External Data#
PyTomography requires using a variety of external data sources to obtain parameters required for tasks like PSF modeling in SPECT and converting CT data to attenuation maps.
NIST#
PyTomography uses data from NIST (link) to get attenuation coefficients for different elemental media and compounds. This is used for (i) obtaining attenuation maps from CT data and (ii) computing a correction factor for collimators that use lead.
SPECT Collimator Data#
Collimator data for SPECT imaging was obtained from the collim.col
file of the SIMIND Monte Carlo program. The values in the “Code” column are used for the collimator_name
argument of theget_psfmeta_from_scanner_params
function from pytomography.io.SPECT
. The supported collimators/codes are listed below.
Scanner |
Code |
Comments |
---|---|---|
Millenium VG kameran |
GV-LEGP |
LOW ENERGY GENERAL PURPOSE |
Millenium VG kameran |
GV-LEHR |
LOW ENERGY HIGH RESOLUTION |
Millenium VG kameran |
GV-EEGP |
EXTENDED LOW ENERGY GENERAL PURPOSE |
Millenium VG kameran |
GV-MEGP |
MEDIUM ENERGY GENERAL PURPOSE |
Millenium VG kameran |
GV-HEGP |
HIGH ENERGY GENERAL PURPOSE |
Millenium VG kameran |
GV-LEUR |
FAN-BEAM LOW-ENERGY ULTRA-HIGH RESOLUTION |
Millenium VG kameran |
GV-UEUH |
ULTRA-HIGH ENERGY ULTRA-HIGH RESOLUTION |
MPR kamera |
GM-LEGP |
LOW ENERGY GENERAL PURPOSE |
MPR kamera |
GM-LEHR |
LOW ENERGY HIGH RESOLUTION |
GE Infinia |
GI-LEHR |
Infinia High Resolution |
GE Infinia |
GI-LEGP |
Infinia General Purpose |
GE Infinia |
GI-MEGP |
Infinia MEGP |
GE Infinia |
GI-HEGP |
Infinia HEGP |
GE Infinia |
GI-ELEG |
Infinia Extended LEGP |
GE Infinia |
GI-LEHX |
Infinia High Resolution |
GE 870 DR |
G8-LHRS |
GE 870 DR High Resolution S |
GE 870 DR |
G8-LEHS |
GE 870 DR High Sensitivity |
GE 870 DR |
G8-LUHR |
GE 870 DR Ultra High Resolution |
GE 870 DR |
G8-LEHR |
GE 870 DR High Resolution |
GE 870 DR |
G8-ELEG |
GE 870 DR Extended General Purpose |
GE 870 DR |
G8-MEGP |
GE 870 DR Medium Energy |
GE 870 DR |
G8-HEGP |
GE 870 DR High Energy |
GE Ventri |
GT-LEHR |
Ventri High Resolution |
GE Ventri |
GT-LEGP |
Ventri General Purpose |
GE 640 Optima |
GO-LEHR |
Ventri High Resolution |
GE 640 Optima |
GO-LEGP |
Ventri General Purpose |
GE 630 |
GO-LEHR |
Ventri High Resolution |
GE 630 |
GT-LEGP |
Ventri General Purpose |
GE 670 CZT |
GZ-LEHR |
CZT Low Energy High Resolution |
CrystalCam CZT |
HH-LEHR |
CZT LE High Resolution (rect) |
CrystalCam CZT |
HH-LEHS |
CZT LE High Sensitivity (rect) |
CrystalCam CZT |
HH-MEGP |
CZT ME General Purpose (circ) |
BW = Philips Brightview camera |
PB-LEGP |
Philips Brightview LEGP |
BW = Philips Brightview camera |
PB-LEHR |
Philips Brightview LEHR |
BW = Philips Brightview camera |
PB-CAHR |
Philips Brightview Cadiac HR |
BW = Philips Brightview camera |
PB-MEGP |
Philips Brightview MEGP |
BW = Philips Brightview camera |
PB-HEGP |
Philips Brightview HEGP |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LEUR |
LOW-ENERGY ULTRA HIGH RESOLUTION |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LEHR |
LOW-ENERGY HIGH RESOLUTION |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LEGP |
LOW-ENERGY GENERAL PURPOSE |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LEHS |
LOW-ENERGY HIGH SENSITIVITY |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LEES |
LOW-ENERGY EXTRA HIGH SENSITIVITY |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LESS |
LOW-ENERGY SUPER HIGH SENSITIVITY |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LEUS |
LOW-ENERGY ULTRA HIGH SENSITIVITY |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-LETY |
LOW-ENERGY THYROID |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-ME23 |
MEDIUM-ENERGY I-123 |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-ME19 |
MEDIUM-ENERGY 190 keV |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-ME26 |
MEDIUM-ENERGY 260 keV |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-ME30 |
MEDIUM-ENERGY 300 keV |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-ME36 |
MEDIUM-ENERGY 360 keV |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-METY |
MEDIUM-ENERGY THYRO333ID |
VG = VON GAHLEN COLLIMATORS - HOLLAND |
VG-HE51 |
HIGH 511 keV |
ENGINEERING DYNAMICS CORPORATION |
ED-LEUR |
LOW-ENERGY ULTRA HIGH RESOLUTION |
ENGINEERING DYNAMICS CORPORATION |
ED-LEHR |
LOW-ENERGY HIGH RESOLUTION |
ENGINEERING DYNAMICS CORPORATION |
ED-LEGP |
LOW-ENERGY GENERAL PURPOSE |
ENGINEERING DYNAMICS CORPORATION |
ED-LEMS |
LOW-ENERGY MEDIUM SENSITIVITY |
ENGINEERING DYNAMICS CORPORATION |
ED-LEHS |
LOW-ENERGY HIGH SENSITIVITY |
ENGINEERING DYNAMICS CORPORATION |
ED-LEUS |
LOW-ENERGY ULTRA HIGH SENSITIVITY |
ENGINEERING DYNAMICS CORPORATION |
ED-MEUS |
MEDIUM-ENERGY ULTRA HIGH SENSITIVITY |
ENGINEERING DYNAMICS CORPORATION |
ED-MEHS |
MEDIUM-ENERGY HIGH SENSITIVITY |
ENGINEERING DYNAMICS CORPORATION |
ED-MEHR |
MEDIUM-ENERGY HIGH RESOLUTION |
ME = MEDISO Nucline SPIRIT DH-V |
ME-LEGP |
Low-Energy General Purpose |
ME = MEDISO Nucline SPIRIT DH-V |
ME-LEHR |
Low-Energy High Resolution |
ME = MEDISO Nucline SPIRIT DH-V |
ME-LEUHR |
Low-Energy Ultra High Resolution |
ME = MEDISO Nucline SPIRIT DH-V |
ME-MEGP |
Medium Energy General Purpose |
ME = MEDISO Nucline SPIRIT DH-V |
ME-HEGP |
High Energy General Purpose |
MA = MEDISO AnyScan |
MA-LEHS |
Low-Energy General Purpose |
MA = MEDISO AnyScan |
MA-LEHR |
Low-Energy High Resolution |
MA = MEDISO AnyScan |
MA-LEUHR |
Low-Energy Ultra High Resolution |
MA = MEDISO AnyScan |
MA-LHRHS |
Low-Energy Ultra High Resolution |
MA = MEDISO AnyScan |
MA-LEGP |
Low-Energy General Purpose |
MA = MEDISO AnyScan |
MA-MLEGP |
Medium Energy General Purpose |
MA = MEDISO AnyScan |
MA-MEGP |
Medium Energy General Purpose |
MA = MEDISO AnyScan |
MA-MHEGP |
Medium Energy General Purpose |
MA = MEDISO AnyScan |
MA-HEGP |
High Energy General Purpose |
PR = PRISM 2000/3000 SYSTEMS |
PR-LEAP |
Low-Energy All Purpose |
PR = PRISM 2000/3000 SYSTEMS |
PR-LEHR |
Low-Energy High Resolution |
PR = PRISM 2000/3000 SYSTEMS |
PR-LEUR |
Low-Energy Ultra-High Res |
PR = PRISM 2000/3000 SYSTEMS |
PR-ME |
Medium Energy |
PR = PRISM 2000/3000 SYSTEMS |
PR-HE |
High Energy |
PR = PRISM 2000/3000 SYSTEMS |
PR-APFB |
All Purpose Fan-Beam |
PR = PRISM 2000/3000 SYSTEMS |
PR-HRFB |
High Resolution Fan-Beam |
PR = PRISM 2000/3000 SYSTEMS |
PR-URFB |
UltraHigh Resol Fan-Beam |
SI = SIEMENS MEDICAL SYSTEM |
SI-LEAP |
Low-Energy All Purpose |
SI = SIEMENS MEDICAL SYSTEM |
SI-LEHR |
Low-Energy High Resolution |
SI = SIEMENS MEDICAL SYSTEM |
SI-ME |
Medium Energy Parallel |
SI = SIEMENS MEDICAL SYSTEM |
SI-ME+ |
Medium Energy Parallel E.CAM+ |
SI = SIEMENS MEDICAL SYSTEM |
SI-HE |
High Energy Parallel |
SI = SIEMENS MEDICAL SYSTEM |
SI-HEGP |
High Energy Parallel |
SI = SIEMENS MEDICAL SYSTEM |
SI-511 |
511 keV Collimator |
SI = SIEMENS MEDICAL SYSTEM |
SI-512 |
511 keV Collimator |
SI = SIEMENS MEDICAL SYSTEM |
SI-THER |
Therapy Collimator |
SI = SIEMENS MEDICAL SYSTEM |
SI-DELU |
Test |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-LEHS |
Low-Energy High Sensitivity |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-LEAP |
Low-Energy All Purpose |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-LEHR |
Low-Energy High Resolution |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-LEUR |
Low-Energy Ultra-High Resolution |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-LEFB |
Low-Energy Fan-Beam |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-ME |
Medium Energy |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-HE |
High Energy |
SE = E.CAM SIEMENS MEDICAL SYSTEM |
SE-UHE |
Ultra-High Energy |
SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS |
SY-LEAP |
Low-Energy All Purpose |
SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS |
SY-LEHR |
Low-Energy High Resolution |
SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS |
SY-ME |
Medium Energy Parallel |
SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS |
SY-HE |
High Energy Parallel |
SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS |
SY-HE1 |
High Energy Parallel |
SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS |
SY-HE2 |
High Energy Parallel |