.. _collimator-data-index: ++++++++++++ Collimator Codes ++++++++++++ Collimator data for SPECT imaging was obtained from the ``collim.col`` file of the SIMIND Monte Carlo program. The values in the "Code" column are used for the ``collimator_name`` argument of the ``get_psfmeta_from_scanner_params`` function from ``pytomography.io.SPECT``. The supported collimators/codes are listed below. .. list-table:: Scanner Codes :widths: 25 25 50 :header-rows: 1 * - Scanner - Code - Comments * - Millenium VG kameran - GV-LEGP - LOW ENERGY GENERAL PURPOSE * - Millenium VG kameran - GV-LEHR - LOW ENERGY HIGH RESOLUTION * - Millenium VG kameran - GV-EEGP - EXTENDED LOW ENERGY GENERAL PURPOSE * - Millenium VG kameran - GV-MEGP - MEDIUM ENERGY GENERAL PURPOSE * - Millenium VG kameran - GV-HEGP - HIGH ENERGY GENERAL PURPOSE * - Millenium VG kameran - GV-LEUR - FAN-BEAM LOW-ENERGY ULTRA-HIGH RESOLUTION * - Millenium VG kameran - GV-UEUH - ULTRA-HIGH ENERGY ULTRA-HIGH RESOLUTION * - MPR kamera - GM-LEGP - LOW ENERGY GENERAL PURPOSE * - MPR kamera - GM-LEHR - LOW ENERGY HIGH RESOLUTION * - GE Infinia - GI-LEHR - Infinia High Resolution * - GE Infinia - GI-LEGP - Infinia General Purpose * - GE Infinia - GI-MEGP - Infinia MEGP * - GE Infinia - GI-HEGP - Infinia HEGP * - GE Infinia - GI-ELEG - Infinia Extended LEGP * - GE Infinia - GI-LEHX - Infinia High Resolution * - GE 870 DR - G8-LHRS - GE 870 DR High Resolution S * - GE 870 DR - G8-LEHS - GE 870 DR High Sensitivity * - GE 870 DR - G8-LUHR - GE 870 DR Ultra High Resolution * - GE 870 DR - G8-LEHR - GE 870 DR High Resolution * - GE 870 DR - G8-ELEG - GE 870 DR Extended General Purpose * - GE 870 DR - G8-MEGP - GE 870 DR Medium Energy * - GE 870 DR - G8-HEGP - GE 870 DR High Energy * - GE Ventri - GT-LEHR - Ventri High Resolution * - GE Ventri - GT-LEGP - Ventri General Purpose * - GE 640 Optima - GO-LEHR - Ventri High Resolution * - GE 640 Optima - GO-LEGP - Ventri General Purpose * - GE 630 - GO-LEHR - Ventri High Resolution * - GE 630 - GT-LEGP - Ventri General Purpose * - GE 670 CZT - GZ-LEHR - CZT Low Energy High Resolution * - CrystalCam CZT - HH-LEHR - CZT LE High Resolution (rect) * - CrystalCam CZT - HH-LEHS - CZT LE High Sensitivity (rect) * - CrystalCam CZT - HH-MEGP - CZT ME General Purpose (circ) * - BW = Philips Brightview camera - PB-LEGP - Philips Brightview LEGP * - BW = Philips Brightview camera - PB-LEHR - Philips Brightview LEHR * - BW = Philips Brightview camera - PB-CAHR - Philips Brightview Cadiac HR * - BW = Philips Brightview camera - PB-MEGP - Philips Brightview MEGP * - BW = Philips Brightview camera - PB-HEGP - Philips Brightview HEGP * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LEUR - LOW-ENERGY ULTRA HIGH RESOLUTION * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LEHR - LOW-ENERGY HIGH RESOLUTION * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LEGP - LOW-ENERGY GENERAL PURPOSE * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LEHS - LOW-ENERGY HIGH SENSITIVITY * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LEES - LOW-ENERGY EXTRA HIGH SENSITIVITY * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LESS - LOW-ENERGY SUPER HIGH SENSITIVITY * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LEUS - LOW-ENERGY ULTRA HIGH SENSITIVITY * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-LETY - LOW-ENERGY THYROID * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-ME23 - MEDIUM-ENERGY I-123 * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-ME19 - MEDIUM-ENERGY 190 keV * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-ME26 - MEDIUM-ENERGY 260 keV * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-ME30 - MEDIUM-ENERGY 300 keV * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-ME36 - MEDIUM-ENERGY 360 keV * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-METY - MEDIUM-ENERGY THYRO333ID * - VG = VON GAHLEN COLLIMATORS - HOLLAND - VG-HE51 - HIGH 511 keV * - ENGINEERING DYNAMICS CORPORATION - ED-LEUR - LOW-ENERGY ULTRA HIGH RESOLUTION * - ENGINEERING DYNAMICS CORPORATION - ED-LEHR - LOW-ENERGY HIGH RESOLUTION * - ENGINEERING DYNAMICS CORPORATION - ED-LEGP - LOW-ENERGY GENERAL PURPOSE * - ENGINEERING DYNAMICS CORPORATION - ED-LEMS - LOW-ENERGY MEDIUM SENSITIVITY * - ENGINEERING DYNAMICS CORPORATION - ED-LEHS - LOW-ENERGY HIGH SENSITIVITY * - ENGINEERING DYNAMICS CORPORATION - ED-LEUS - LOW-ENERGY ULTRA HIGH SENSITIVITY * - ENGINEERING DYNAMICS CORPORATION - ED-MEUS - MEDIUM-ENERGY ULTRA HIGH SENSITIVITY * - ENGINEERING DYNAMICS CORPORATION - ED-MEHS - MEDIUM-ENERGY HIGH SENSITIVITY * - ENGINEERING DYNAMICS CORPORATION - ED-MEHR - MEDIUM-ENERGY HIGH RESOLUTION * - ME = MEDISO Nucline SPIRIT DH-V - ME-LEGP - Low-Energy General Purpose * - ME = MEDISO Nucline SPIRIT DH-V - ME-LEHR - Low-Energy High Resolution * - ME = MEDISO Nucline SPIRIT DH-V - ME-LEUHR - Low-Energy Ultra High Resolution * - ME = MEDISO Nucline SPIRIT DH-V - ME-MEGP - Medium Energy General Purpose * - ME = MEDISO Nucline SPIRIT DH-V - ME-HEGP - High Energy General Purpose * - MA = MEDISO AnyScan - MA-LEHS - Low-Energy General Purpose * - MA = MEDISO AnyScan - MA-LEHR - Low-Energy High Resolution * - MA = MEDISO AnyScan - MA-LEUHR - Low-Energy Ultra High Resolution * - MA = MEDISO AnyScan - MA-LHRHS - Low-Energy Ultra High Resolution * - MA = MEDISO AnyScan - MA-MEGP - Medium Energy General Purpose * - MA = MEDISO AnyScan - MA-HEGP - High Energy General Purpose * - MA = MEDISO AnyScan - MA-HLR - High Energy High Resolution * - GE Discovery NM630 - D-LEGP - Low Energy General Purpose * - GE Discovery NM630 - D-LEHR - Low Energy High Resolution * - GE Discovery NM630 - D-MEGP - Medium Energy General Purpose * - GE Discovery NM630 - D-HEGP - High Energy General Purpose * - GE Discovery NM630 - D-UHEGP - Ultra High Energy General Purpose * - PR = PRISM 2000/3000 SYSTEMS - PR-HRFB - High Resolution Fan-Beam * - PR = PRISM 2000/3000 SYSTEMS - PR-URFB - UltraHigh Resol Fan-Beam * - SI = SIEMENS MEDICAL SYSTEM - SI-LEAP - Low-Energy All Purpose * - SI = SIEMENS MEDICAL SYSTEM - SI-LEHR - Low-Energy High Resolution * - SI = SIEMENS MEDICAL SYSTEM - SI-ME - Medium Energy Parallel * - SI = SIEMENS MEDICAL SYSTEM - SI-ME+ - Medium Energy Parallel E.CAM+ * - SI = SIEMENS MEDICAL SYSTEM - SI-HE - High Energy Parallel * - SI = SIEMENS MEDICAL SYSTEM - SI-HEGP - High Energy Parallel * - SI = SIEMENS MEDICAL SYSTEM - SI-511 - 511 keV Collimator * - SI = SIEMENS MEDICAL SYSTEM - SI-512 - 511 keV Collimator * - SI = SIEMENS MEDICAL SYSTEM - SI-THER - Therapy Collimator * - SI = SIEMENS MEDICAL SYSTEM - SI-DELU - Test * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-LEHS - Low-Energy High Sensitivity * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-LEAP - Low-Energy All Purpose * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-LEHR - Low-Energy High Resolution * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-LEUR - Low-Energy Ultra-High Resolution * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-LEFB - Low-Energy Fan-Beam * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-ME - Medium Energy * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-HE - High Energy * - SE = E.CAM SIEMENS MEDICAL SYSTEM - SE-UHE - Ultra-High Energy * - SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS - SY-LEAP - Low-Energy All Purpose * - SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS - SY-LEHR - Low-Energy High Resolution * - SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS - SY-ME - Medium Energy Parallel * - SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS - SY-HE - High Energy Parallel * - SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS - SY-HE1 - High Energy Parallel * - SY = SIEMENS MEDICAL SYSTEM SYMBIA COLLIMATORS - SY-HE2 - High Energy Parallel